- Overview
- Product Description
- About us
- Why choose us
- Workshop
- Certifications
- Exhibition & Our Team
- Project cases & Our Customer
- Packaging & Shipping
Basic Info.
Model NO.
MY-Autoclave
Sterilization Information Recording and Printing
Sterilization Information Recording and Printing
Material
Stainless Steel
Sterilization Concentration Curve Range
0-1000 Ppm
UV Lamp
1PC/30W
Work Pressure
0kpa to 60kpa
Working Humidity
20-90
Sterilization Cycle Time
Less Than 120 Min
Transport Package
Wooden Case
Specification
5120 X 2020 X 2320mm
Trademark
marya
Origin
China
Product Description
Marya Advanced Pharmaceutical Sterilizer High-Tech PLC-Controlled Steam Autoclave for Sterilization
Main Applications
An Autoclave sterilizer is a device that can kill or remove all microorganisms on the media, including bacterial spores and non-pathogenic microorganisms. Generally, there are three ways of sterilization: damp-heat sterilization, dry-heat sterilization and chemical sterilization. The sterilizing cabinet can be used in many fields, such as pharmacy, medical treatment, biology, food and so on, in line with the relevant requirements of the national GMP verification and special equipment safety supervision, health and epidemic prevention departments.
Sterilizing cabinet mainly has water bath type, rapid cooling, ampoule (oral liquid) sterilization leak detection, pure steam, Chinese patent medicine, pulsating vacuum and other specifications, suitable for large infusion (including automatic logistics line), water injection, oral liquid, canned food, biological products, culture medium, Chinese patent medicine, condiment, medical devices ,100 class clean area of sterile clothing and experimental equipment and other products or utensils sterilization operation. Features
♠ The whole machine design, material, manufacture, assembly, commissioning and so on are in line with the new GMP and FDA drug production specifications;
♠ Effective loading capacity of pulsating vacuum sterilizer: 0.24 m³-6m³;
♠ Effective capacity of dry heat sterilizer: 0.4 m³-3.5m³;
♠ Effective loading capacity of water bath sterilizer: 0.6 m³-15m³;
♠ The sterilizing cabinet adopts particular door seal design structure to avoid the risk of leakage in the chamber of sterilizing cabinet;
♠ The sterilizer adopts the advanced automatic control system, automatically controls the temperature, and automatically maintains the inner cavity positive pressure;
♠ The sterilizing cabinet adopts an intelligent drying system, the residual humidity after drying is not more than 0.2, and the residual humidity after drying the auxiliary materials is not more than 1;
♠ Sterilizer has temperature, pressure, time, and other aspects of detection alarm function;
♠ Sterilizer accurate temperature control, stable operation, and has sound sterilization records;
♠ A GMP verification interface is left on the sterilizing cabinet equipment to facilitate the verification of the equipment;
♠ The sealing door of sterilizing cabinet can adopt the structure of mobile door or translation door;
Specification
Main Applications
An Autoclave sterilizer is a device that can kill or remove all microorganisms on the media, including bacterial spores and non-pathogenic microorganisms. Generally, there are three ways of sterilization: damp-heat sterilization, dry-heat sterilization and chemical sterilization. The sterilizing cabinet can be used in many fields, such as pharmacy, medical treatment, biology, food and so on, in line with the relevant requirements of the national GMP verification and special equipment safety supervision, health and epidemic prevention departments.
Sterilizing cabinet mainly has water bath type, rapid cooling, ampoule (oral liquid) sterilization leak detection, pure steam, Chinese patent medicine, pulsating vacuum and other specifications, suitable for large infusion (including automatic logistics line), water injection, oral liquid, canned food, biological products, culture medium, Chinese patent medicine, condiment, medical devices ,100 class clean area of sterile clothing and experimental equipment and other products or utensils sterilization operation.
♠ The whole machine design, material, manufacture, assembly, commissioning and so on are in line with the new GMP and FDA drug production specifications;
♠ Effective loading capacity of pulsating vacuum sterilizer: 0.24 m³-6m³;
♠ Effective capacity of dry heat sterilizer: 0.4 m³-3.5m³;
♠ Effective loading capacity of water bath sterilizer: 0.6 m³-15m³;
♠ The sterilizing cabinet adopts particular door seal design structure to avoid the risk of leakage in the chamber of sterilizing cabinet;
♠ The sterilizer adopts the advanced automatic control system, automatically controls the temperature, and automatically maintains the inner cavity positive pressure;
♠ The sterilizing cabinet adopts an intelligent drying system, the residual humidity after drying is not more than 0.2, and the residual humidity after drying the auxiliary materials is not more than 1;
♠ Sterilizer has temperature, pressure, time, and other aspects of detection alarm function;
♠ Sterilizer accurate temperature control, stable operation, and has sound sterilization records;
♠ A GMP verification interface is left on the sterilizing cabinet equipment to facilitate the verification of the equipment;
♠ The sealing door of sterilizing cabinet can adopt the structure of mobile door or translation door;
Specification